Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Tissue Engineering Research ; (53): 846-851, 2018.
Article in Chinese | WPRIM | ID: wpr-698464

ABSTRACT

BACKGROUND:Bio-Oss bone substitutes have been shown to prevent bone resorption by slowing bone resorption,reducing bone resorption,and restoring the height of the alveolar ridge.However,most clinical studies focus on the efficacy within 1-3 months.OBJECTIVE:To compare the effects of two kinds of bone substitutes on the height of alveolar ridge and the periodontal tissue health status after implantation into the extraction socket of the wisdom tooth.METHODS:Forty patients with impacted mandibular teeth were randomly divided into two groups:Bio-Oss Collagen material was implanted in experimental group (n=20),and Bio-Oss bone replacement materials in control group (n=20).Cone-beam CT was retrospectively reviewed at 1,3 and 12 months after implantation.Alveolar bone height,bone changes and the second molars mobility were examined.Meanwhile,healing status of tooth extraction and gingival mucosa as well as the material spills were observed.RESULTS AND CONCLUSION:(1) At 1 month after implantation,the gingival mucosa of both groups healed well without swelling.There was no spillover in the experimental group,while there were two cases of bone material spill in the control group.No tissues generated in the extraction socket and tooth loosening was observed in both groups.(2) At 3 months after implantation,the materials gradually degraded with no swelling and with generation of partial bone tissues in the experimental group,and the tooth mobility was improved.In the control group,there was also no swelling in the gums,and the materials degraded partially,but there was no presence of new bone and no improvement in the tooth mobility.(3) At 12 months after implantation,there was no swelling in the gums of the experimental group,obvious new bone tissues formed in the second molar with the presence of bone trabecula.The new bone tissues were integrated with the surrounding bone tissues.The crest of the alveolar ridge was located about 3 mm below the enamel cementum,the tooth mobility was restored to the level before extraction,and the chewing function recovered.In the control group,there was no swelling in the gums,and new bone tissues formed in the distal part of the molar,but the trabecular arrangement was not aligned.The crest of the alveolar was located about 3 mm below the enamel cementum,the tooth mobility returned to the pre-extraction level,and the chewing function was normal.(4) The height of the alveolar bone at 1 and 3 months after implantation was significantly higher in the experimental group than the control group (P < 0.01),while there was no significant difference between the two groups at 12 months after implantation.To conclude,implantation of Bio-Oss Collagen immediately after removal of the impacted wisdom tooth of the mandible is beneficial to alveolar bone height and bone quality recovery,and significantly improves the periodontal health of the second molar,but the long-term effect needs further observation.

2.
Chinese Traditional and Herbal Drugs ; (24): 913-917, 2017.
Article in Chinese | WPRIM | ID: wpr-852941

ABSTRACT

Objective: To optimize the processing technology of Hemsleya omeiensis processed by licorice juice. Methods: HPLC was employed to determine the content of hemslecin A.Taking content of hemslecin A as index, the orthogonal test was adopted to optimize the covered moistening time, drying-time, and processing temperature. And the central composite design-response surface methodology (CCD-RSM) was adapted to optimize moistening time and drying-time further. Results: The optimum processing technology of H. omeiensis by the orthogonal test was covered moistening time of 7 h, drying-time of 12 h, and processing temperature at 80℃. The optimum processing technology by CCD-RSM was covered moistening time of 7.48-8.56 h, drying-time of 12.06-13.12 h, and processing temperature at 80℃. Conclusion: The experimental design method is precise and the data are reliable with the model. It is the first time that H. omeiensis is processed with licorice juice. Besides, it establishes the processing technology of H. omeiensis and provides a theoretical basis for the processing technology of H. omeiensis with licorice juice.

3.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 2095-2100, 2010.
Article in Chinese | WPRIM | ID: wpr-635093

ABSTRACT

Objective To investigate the change of cardiac function in elderly hypertensive patients with heart valve degenerative by echocardiography.Methods A total of 126 cases were divided into a valve disease group and non-valve disease group groups.The parameters of trial size,cardiac function and pulmonary artery pressure were detected.Results Of all 126 cases were the patients with hypertension including 28.6% (36/126) of valve disease group and 71.4% (90/126) of non-valve disease.There were 31 cases with mitral valve disease,22 cases with tricuspid valve disease; 26 cases with aortic valve disease; 36 cases with double or three alvular lesions in valve disease group.There was a significant difference in ventricle size and systolic function among valve disease group and non-valve disease group and control group.But there was no significant difference in thickness of ventricular wall between valve disease group and non-valve disease group.Conclusion The elderly hypertensive patient with valve disease was an independent factor for the development of congestive heart failure.

SELECTION OF CITATIONS
SEARCH DETAIL